Fire Door Survey at 8 Finsbury Circus, London – 140 Communal Fire Doors Inspected for Compliance

Project Overview – Large-Scale Fire Door Survey in a Commercial Building

This project involved a comprehensive fire door survey at 8 Finsbury Circus, a prominent commercial property in central London. The purpose of the survey was to assess the condition, performance, and compliance of all communal fire doors throughout the building and to confirm alignment with current UK fire safety regulations.

Project Location – 8 Finsbury Circus, London

  • Commercial office and communal building
  • High-occupancy, multi-storey environment with shared escape routes and plant areas

Scope of Fire Door Survey Works – Communal Areas and Service Zones

The survey covered all communal fire doors within the building, including corridors, stairwells, plant rooms, and service areas.

Survey ItemDetails
Total fire doors surveyed140
Door locationsCommunal corridors, staircases, plant rooms
Door typesTimber fire doors and metal fire doors
Building typeCommercial office building
Survey purposeCompliance, safety and performance assessment

What the Fire Door Survey Included

Each fire door was individually inspected in line with best practice guidance and current legislation. The survey assessed both visual condition and functional performance to identify any non-compliances or maintenance requirements.

Key checks carried out during the survey included:

• Door leaf condition and integrity
• Door frame condition and fixing
• Gaps around door edges and thresholds
• Presence and condition of intumescent and smoke seals
• Hinges, handles, closers and fire-rated ironmongery
• Self-closing operation and latch engagement
• Door signage and fire safety markings
• General suitability for use as a fire-resisting door

Where required, measurements were taken to confirm tolerances, and detailed notes were recorded for each door.

Why a Fire Door Survey Was Required

Fire doors play a critical role in compartmentation and safe evacuation within commercial buildings. Due to the size and occupancy of the building, a fire door survey was required to:

• Confirm compliance with current fire safety regulations
• Support the building’s fire risk assessment
• Identify any defects or non-compliant doors
• Reduce liability for the building owner or managing agent
• Prioritise remedial works where required
• Ensure escape routes remain protected

Regular fire door inspections are a legal and practical requirement for large communal buildings.

Fire Door Compliance Standards Considered During the Survey

Compliance AreaStandard / Requirement
Fire safety legislationRegulatory Reform (Fire Safety) Order 2005
Door performanceCorrect fire resistance for location
Smoke controlEffective intumescent and smoke seals
OperationReliable self-closing and latching
MaintenanceDoors fit for continued safe use

All findings were assessed against current guidance and industry best practice.

Survey Findings and Reporting Outcome

Following completion of the survey, a detailed written report was produced covering all 140 fire doors. The report provided:

• A clear pass/fail status for each fire door
• Photographic evidence where relevant
• Identification of defects and non-compliances
• Clear recommendations for remedial works
• A practical overview to assist with compliance planning

This enables the client to take informed action and maintain ongoing fire safety standards across the building.

This project demonstrates our experience delivering large-scale fire door surveys for complex commercial buildings, ensuring safety, compliance, and clear reporting for property owners and managing agents.

Tags :
Fire Prevention, Job, London
Share This :